Concrete Column Calculator

Work out the concrete, the steel cage and the formwork for round, square or rectangular concrete columns. Enter the size, the number of columns and the bars, press Calculate, and see the cubic metres, the main bars and links, the tie wire, the column formers or plywood, and the cost, with quick checks against the usual detailing rules.

Column Shape

Steel Cage

Main Bar Size
Link Size
mm
mm

Use the bar sizes and spacing on your engineer's drawing. 40 mm cover suits most outdoor columns; use 50 mm or more where the concrete touches the ground.

Enter The Size

mm
m
Mix If You Make It Yourself (Cement : Ballast)
%

Columns are cast in a form, so 5% is usually enough.

Prices (Optional)
£
£

Added for each m³ under 4 m³.

£
£
£
£

2440 × 1220 mm shuttering ply.

Concrete columns are structural. This calculator works out quantities and checks a few common rules; the design must come from a structural engineer and be approved by Building Control.

How To Use The Concrete Column Calculator

  1. Choose the shape: square, rectangular or round.
  2. Set up the steel cage from your drawing: the number and size of main bars, the link size and spacing, and the cover.
  3. Enter the column size, the height and how many columns there are.
  4. Press Calculate Column. Change any prices to match your quotes.

You get the concrete in cubic metres with three ways to buy it, the main bars and links with their lengths and weight, the tie wire, the column formers or plywood, and the material cost. A drawing shows the column and a section through the cage, and six quick checks flag anything outside the usual detailing limits.

Concrete Per Metre Of Column

ColumnAreaConcrete per metreWeight per metre
Ø 200 mm round0.031 m²31 litres75 kg
Ø 250 mm round0.049 m²49 litres118 kg
Ø 300 mm round0.071 m²71 litres170 kg
Ø 400 mm round0.126 m²126 litres302 kg
200 × 200 mm square0.040 m²40 litres96 kg
250 × 250 mm square0.063 m²63 litres150 kg
300 × 300 mm square0.090 m²90 litres216 kg
400 × 400 mm square0.160 m²160 litres384 kg

Multiply by the height and the number of columns. Four 300 mm square columns 2.4 m high need 4 × 0.09 × 2.4 = 0.86 m³, or about 0.9 m³ with 5% extra. A round column holds about 21% less concrete than a square column of the same width.

The Steel Cage

A reinforced concrete column has vertical main bars, which carry load with the concrete, and links (also called ties or stirrups), which wrap round the main bars and stop them buckling outwards. The cage sits inside a layer of concrete called the cover, which protects the steel from rust and fire.

At the bottom, the main bars lap onto starter bars cast into the foundation. The calculator adds a lap of 40 bar diameters to each main bar, which is 640 mm for an H16 bar; your engineer may ask for a different lap. Each link includes about 24 link diameters for its hooks. For a full cutting list, or for slabs and walls, use our rebar calculator.

Column Detailing Rules Of Thumb

RuleUsual limit
Number of main barsAt least 4, one in each corner; usually 6 or more in a round column
Main bar sizeAt least 12 mm in the UK
Link sizeAt least 6 mm and a quarter of the main bar size
Link spacingNo more than 20 × the smallest main bar, the column width or 400 mm, whichever is least
Steel areaBetween about 0.2% and 4% of the column section
CoverTypically 30–40 mm, 50 mm or more against the ground

These are the common detailing limits from Eurocode 2 and its UK National Annex, which the calculator checks. Passing them does not mean a column is strong enough: that depends on the load, the height and the concrete, and needs a structural engineer.

Reinforcement Bar Weights

BarWeight per metreTypical use in columns
H80.395 kgLinks
H100.617 kgLinks for bigger bars
H120.888 kgMain bars in small columns
H161.579 kgMain bars in most house columns
H202.466 kgMain bars in heavier columns
H253.854 kgMain bars in large columns

Bar weight is 0.00617 × diameter² kg per metre. Bars are sold in stock lengths of 6 m or 12 m, or cut and bent to a schedule. Ready-made links save time on site.

Formwork For Concrete Columns

Round columns are usually cast in spiral-wound cardboard column formers. They come in 3 m lengths in diameters from about 150 mm up, are cut to height, braced plumb, then peeled off once the concrete has set. They are single-use, so the calculator counts one per column, or more for columns over 3 m.

Square and rectangular columns are usually boxed in 18 mm shuttering plywood, clamped and braced. The calculator works out the plywood area from the column's outside edge × height × number of columns, plus 10% for cutting. Good plywood boxes can be reused several times, so the cost for many columns may be lower than shown. Our concrete formwork calculator covers boxing for slabs, footings and steps.

Concrete And Pouring

Structural columns are normally specified as C25/30 or C32/40, which is best bought as ready-mix with a certificate. For small piers and posts that are not structural, a site mix of 1 part cement to 4 parts all-in ballast is a strong general mix. Columns hold little concrete, so a few small columns often fall below a ready-mix minimum load; the calculator compares ready-mix, mixing on site and 20 kg bags so you can see the cheapest.

  • Pour tall columns in lifts of about 1.5–2 m, and vibrate or rod each lift so there are no voids.
  • Do not drop concrete from a great height down a narrow column; it separates and leaves honeycombing at the base.
  • Leave formers on for at least a few days, and keep the concrete damp while it cures.

Concrete Column Costs In 2026

ItemTypical 2026 UK price
Ready-mix concrete, per m³£100–£160, plus part-load under the minimum
H16 rebar, per metre£4–£6
H8 links, per metre£1.50–£2.50
Cardboard column former, 3 mAbout £45–£150, by diameter
18 mm shuttering plywood sheet£40–£55
Tie wire, 1 kg roll£5–£8

Former prices vary a lot between suppliers and diameters, so the calculator's default is only a guide; enter your own quote. Labour, cutting and bending, cranes or pumps are not included.

Engineers And Building Control

Columns hold up beams, floors and roofs, so they come under Part A of the Building Regulations. A structural engineer should size the column, its bars and links, and its foundation, and Building Control will usually want to see the calculations and inspect the steel before you pour. The government's Approved Document A explains the structural requirements. Use this calculator to price and order materials from an engineer's design, not to design the column.

How The Calculator Works

Concrete = section area × height × number of columns × (1 + extra %) · Round area = 3.1416 × diameter² ÷ 4

Main bar length = height + 40 × bar diameter · Links per column = height ÷ spacing + 1, rounded down then plus one

Link length = cage perimeter inside the cover + 24 × link diameter · Steel (kg) = metres × 0.00617 × d²

Ties are one per crossing of a main bar and a link, at about 250 ties per kilogram of wire. Concrete for site mixing uses a dry volume of 1.25 × the wet volume, cement at 1,440 kg/m³ and ballast at 1.7 t/m³, the same as our concrete calculator. Ready-mix is ordered in 0.25 m³ steps, charged at a 1 m³ minimum, with your part-load charge below 4 m³.

Concrete Column Calculator FAQs

How much concrete is in a column?

Section area × height. A 300 mm square column 2.4 m high holds 0.3 × 0.3 × 2.4 = 0.216 m³. A 300 mm round column the same height holds 0.170 m³.

How many bars are needed in a concrete column?

At least four, one in each corner of a square or rectangular column. Round columns usually have six or more. The engineer sets the actual number and size.

What size rebar is used in columns?

Main bars are at least 12 mm in the UK, and H16 is common in house columns. Links are often H8, and must be at least a quarter of the main bar size.

What is the maximum spacing of links in a column?

Under Eurocode 2 and the UK National Annex, no more than 20 times the smallest main bar, the least width of the column, or 400 mm, whichever is smallest. That is 320 mm for H16 bars.

How much cover does a column need?

Typically 30–40 mm to the links for columns above ground, and 50 mm or more where concrete is cast against the ground. The engineer sets it for the exposure.

What concrete mix should I use for columns?

Structural columns are usually C25/30 or C32/40 ready-mix. For small non-structural piers, a site mix of 1:4 cement to all-in ballast is suitable.

How do you make a round concrete column?

Stand a cardboard column former over the starter bars, drop the cage inside, brace it plumb, then fill it in lifts while vibrating. Strip the tube after a few days.

Do I need an engineer for a concrete column?

Yes, for any column that carries a building. The engineer designs it, and Building Control approves the design and inspects the work.

More Calculators

Detailing limits follow Eurocode 2 (BS EN 1992-1-1) and its UK National Annex. Bar weights use 0.00617 × d² kg/m. Concrete figures match the rest of ConstructionMath. Default prices are typical 2026 UK prices including VAT; column former prices vary widely, so check with your supplier. Reviewed November 2026.