Free UK construction calculators Metric and imperial 2026 UK prices

Guttering Calculator

Work out what size gutter your roof needs and exactly what to buy. Enter the length of guttering, the number of runs, corners and downpipes, and the roof size and pitch, then press Calculate for the gutter size to Approved Document H and a full parts list with prices.

Your Guttering

m

All the eaves you are guttering, added together.

no.

Front and back of a house = 2.

no.

Where a run turns round the building.

no.
m

About 2.5 m for a bungalow or extension and 5 m for a two-storey house.

Downpipe Position

Roof Draining Into The Gutter

m

Measured flat, as on a plan: usually half the width of the house for a roof that slopes both ways.

°

Bracket Spacing

Parts are for the common 112 mm half-round plastic system with 68 mm round downpipes. The gutter size check follows Approved Document H for England and Wales.

How To Use The Guttering Calculator

  1. Measure the eaves you are guttering and add them up. Enter how many separate runs that makes (each run has two ends), and how many corners it goes round.
  2. Enter the number of downpipes and whether they sit at the ends of the runs or part way along.
  3. Enter the gutter height above the ground, so the downpipe lengths can be worked out.
  4. Enter the roof depth and pitch. The depth is the flat distance from the gutter to the ridge; for a normal pitched roof it is half the width of the house.
  5. Choose the bracket spacing and press Calculate Guttering.

The result shows the effective roof area and rainfall, the gutter and outlet size Approved Document H asks for, whether a standard 112 mm gutter is big enough, and a full parts list with quantities and prices. The drawing shows one run with every bracket, joint and downpipe.

What Size Gutter Do I Need?

In England and Wales, Approved Document H (Drainage and waste disposal), Section H3, sets out how big gutters should be for a design rainfall of 75 mm an hour. Table 2 gives the largest effective roof area that each size of level half-round gutter can drain through an outlet at one end:

Max effective roof areaGutter sizeOutlet sizeFlow
6 m²No gutter needed––
18 m²75 mm50 mm0.38 l/s
37 m²100 mm63 mm0.78 l/s
53 m²115 mm63 mm1.11 l/s
65 m²125 mm75 mm1.37 l/s
103 m²150 mm89 mm2.16 l/s

Most UK homes use a 112 mm half-round plastic gutter with a 68 mm round downpipe, which is bigger than the 100 mm row. Makers such as FloPlast publish their own tested figures: their 112 mm half-round with an end outlet carries about 0.82 l/s laid level and 1.05 l/s with a fall, rising to 1.62 and 2.34 l/s with a running outlet in the middle of the run. Deep-flow and high-capacity profiles of 115 to 125 mm carry more, and 150 mm gutters are used on large and commercial roofs.

Working Out Effective Roof Area

Rain falls at a slant in wind, so a steep roof catches more than its plan area suggests. Approved Document H allows for this with a pitch factor (Table 1), which is the same as the formula used by gutter makers:

Effective area = (W + H ÷ 2) × L

where W is the flat depth from gutter to ridge, H is the height from gutter to ridge and L is the length of the gutter. For a 35° roof 4 m deep, H is 2.8 m, so each metre of gutter drains (4 + 1.4) = 5.4 m² of effective roof.

RoofEffective area
FlatPlan area × 1.0
30° pitchPlan area × 1.29
45° pitchPlan area × 1.50
60° pitchPlan area × 1.87
Over 70° or a wallElevation area × 0.5

The flow to carry is then the effective area × 0.0208 litres a second (75 mm an hour). A 43 m² roof slope gives about 0.9 l/s.

How Many Downpipes?

Each downpipe can only take the water a gutter can bring to it, so a long or steep roof needs more than one. Putting the outlet in the middle of a run instead of at the end roughly doubles the roof area one downpipe can serve, because water flows to it from both directions and each half of the gutter carries only half the water.

Gutter runEffective areaDownpipes needed
6 m32 m²1 at the end
8 m43 m²2 at the ends, or 1 in the middle
12 m65 m²2 at the ends, or 1 in the middle
16 m86 m²3, or 2 in the middle

The figures follow the Approved Document H table, which is cautious for modern plastic gutters. Where the calculator says a 112 mm gutter needs more downpipes, you can either add them or switch to a deep-flow gutter of the size shown.

Guttering Parts Explained

  • Gutter lengths: usually 4 m (2 m and 3 m are also sold). Cut with a fine saw and mark the insertion depth on each union.
  • Fascia brackets: hold the gutter to the fascia at no more than 1 m apart, 800 mm where heavy snow is likely, and within 150 mm of every joint, angle and outlet.
  • Union brackets: join two lengths with a rubber seal and leave room for expansion.
  • Stop ends: close the ends of a run. A stop end outlet closes the end and takes a downpipe at the same time.
  • Running outlet: an outlet part way along a run that also joins two lengths.
  • Angles: 90° and 135° corners for going round the building.
  • Offset bends: two 112.5° bends and a short piece of pipe make the swan neck that brings the downpipe from the gutter back to the wall.
  • Downpipe, clips and shoe: 2.5 m lengths joined with sockets, held by a clip about every 2 m, ending in a shoe over a gully or straight into a drain connector.

How Much Does Guttering Cost?

Plastic guttering is cheap: the calculator uses typical 2026 UK prices for FloPlast 112 mm half-round, including VAT.

PartPrice
Gutter, 4 m£9.85
Fascia bracket£0.80 to £1.00
Union bracket£2.90
Stop end / stop end outlet£2.70 / £4.90
Running outlet£4.00
90° angle£4.40
Downpipe, 2.5 m£8.20
Offset bend / clip / shoe£3.80 / £1.00 / £4.00

The parts for a typical semi-detached house, front and back, come to around £150 to £200. Black, anthracite and cast-iron effect colours cost about the same; deep-flow systems cost roughly a third more, and aluminium or cast iron several times more. Fitting by a roofer, with scaffold, usually costs far more than the materials.

Fitting Tips

  • Fix a string line from a bracket near each outlet, falling about 1 in 350 to 1 in 600 towards it (around 3 to 5 mm per 2 m). Level gutters work, but a slight fall drains better and stops standing water.
  • Position the gutter so the roof edge sits over the middle of it, and so rain running off the tiles lands in it.
  • Leave the expansion gap marked on unions: plastic gutters grow noticeably in summer sun.
  • Fit downpipe clips at every socket and about every 2 m, and make sure the shoe or connector discharges into a gully, drain or soakaway, not against the wall.
  • Clear leaves every autumn, and fit leaf guards near trees.
  • Work from a scaffold tower or platform rather than a ladder for anything above a single storey.

If the water goes to a soakaway, size it with our soakaway calculator.

Guttering FAQs

What size guttering do I need for my house?

Most houses use 112 mm half-round plastic guttering with 68 mm downpipes. A large or steep roof may need a deep-flow 115 to 125 mm gutter, or more downpipes. The calculator checks this against Approved Document H.

How far apart should gutter brackets be?

No more than 1 m apart for plastic half-round gutters, 800 mm in areas with heavy snow, and within 150 mm of every joint, angle and outlet.

How many downpipes do I need?

Enough that the roof area per downpipe stays within the gutter's capacity. For a standard 112 mm gutter that is roughly 40 m² of effective roof per end outlet, or about double with a running outlet in the middle.

How much fall should a gutter have?

About 1 in 350 to 1 in 600 towards the outlet: 3 to 5 mm for every 2 m. A gutter can be fitted level, but it then carries less water.

How do I work out the effective roof area?

Use (W + H ÷ 2) × L, where W is the flat depth from gutter to ridge, H the height from gutter to ridge and L the gutter length.

How much does a 4 m length of guttering cost?

About £9.85 for a 4 m length of 112 mm half-round plastic gutter in 2026, including VAT.

Do I need Building Regulations approval to replace guttering?

Like-for-like replacement of guttering does not normally need approval. New roofs and extensions must have gutters and downpipes that meet Approved Document H.

Can I connect a new downpipe to an existing drain?

Rainwater should go to a surface water drain, a soakaway or a water butt. Do not connect it to a foul drain unless it is a combined system and you have permission.

More Roof Calculators

Gutter sizes and pitch factors from Approved Document H, Section H3, Tables 1 and 2 (75 mm/h design rainfall). FloPlast flow capacities and bracket spacing from FloPlast product data. Prices from UK merchant listings for FloPlast 112 mm half-round, 2026, including VAT. Reviewed November 2026.